APP下载

Enhanced removal of X-ray-induced carbon contamination using radio-frequency Ar/H2plasma

2019-02-27YiWangQiPengLuYunGuoGaoXuePengGongYuanSong

Nuclear Science and Techniques 2019年2期

Yi Wang·Qi-Peng Lu·Yun-Guo Gao·Xue-Peng Gong·Yuan Song

Abstract Removal of X-ray-induced carbon contamination on beamline optics was studied using radio-frequency plasma with an argon/hydrogen(Ar/H2)mixture.Experiments demonstrated that the carbon removal rate with Ar/H2plasma was higher than that with pure hydrogen or argon.The possible mechanism for this enhanced removal was discussed.The key working parameters for Ar/H2 plasma removal were determined,including the optimal vacuum pressure,gas mixing ratio,and source power.The optimal process was performed on a carbon-coated multilayer,and the re flectivity was recovered.

Keywords Radio-frequency plasma·X-ray irradiation·Carbon contamination

1 Introduction

Under X-ray irradiation,residual hydrocarbons in a light source beamline will split into dissociated carbon atoms,which will deposit on the surface of optics to form contamination[1,2].This deposited carbon will result in a severe degradation of the re flectivity.X-ray sources have been developed to provide high energy,high power,and a strong pulse for third-generation synchrotron radiation sources[3,4]and X-ray free-electron laser(XFEL)facilities[5].The improvement in the source has in turn brought a serious challenge to the life of the X-ray optics due to carbon contamination.In order to extend the life of the X-ray optics,high ef ficiency carbon contamination removal methods should be implemented.This study is devoted to investigating the feasibility of high ef ficiency carbon removal with low-pressure plasma.

Practically,it is necessary to remove the carbon with reasonable ef ficiency,while the multilayer optics should not be harmed.Atomic hydrogen has been employed to solve the carbon removal problem[6,7],but the removal rate of carbon contamination with atomic hydrogen is quite low,limiting its practical use.Therefore,radio-frequency(RF)plasma carbon removal technology has been widely studied[8-11].Pellegrin et al.[8]investigated hydrogen and oxygen plasma removal of carbon-deposited specimens and determined that the removal ef ficiency with oxygen plasma was much higher than that with hydrogen plasma.However,there is also a risk of oxidation of the optics material and deterioration of the optical characteristics.Alternatively,the hydrogen plasma removal method could become the preferred one if its removal ef ficiency can be enhanced.The addition of argon to the RF hydrogen plasma is a promising way to improve the removal rate[8,11].The mechanism of this enhancement was speculated in Ref.[8],which proposed that argon improves the transport of hydrogen,while Pradhan et al.[12,13]argued that the enhancement was the result of kinetic effects.

In this study,carbon removal experiments using pure hydrogen,pure argon,and Ar/H2plasma were conducted separately to compare the removal rates with different methods.The optimal parameters for enhanced removal conditions with Ar/H2plasma were determined through a series of experiments.This optimal process was performed on a carbon-coated multilayer.Based on these experimental results,a possible removal mechanism has been proposed to explain the enhancement with Ar/H2plasma.

2 Experimental

In most cases,the type of deposited carbon induced by X-rays is amorphous.Therefore,magnetron-deposited carbon has frequently been used as a model for X-rayinduced carbon growth[3,8,14].Thus,experiments were performed on a quartz wafer and multilayer optics coated with an amorphous carbon film with a thickness between 25 and 75 nm.The carbon film was deposited by a commercial magnetron sputtering source with a polycrystalline graphite target.For the specimens,the changes in the carbon thickness of the carbon-coated quartz wafers were monitored to demonstrate the removal ef ficiency.In addition,optimal parameters were determined using the quartz wafers.The change in re flectivity on the multilayer drives the study of the feasibility of carbon removal using an Ar/H2plasma.

As a plasma source,a commercially available RF plasma generator(Model GV10X ‘‘Downstream Asher'',IBSS,San Francisco,CA,USA)was employed that utilized inductively coupled plasma(ICP).Relative to the specimens in the cleaning chamber,the plasma is generated in a separate volume upstream.The volume of the cleaning chamber is 28L,which is about 1000 times larger than that of the plasma chamber.A small ori fice is located between the plasma chamber and the cleaning chamber,with a diameter of only 1 mm.The pressure in the cleaning chamber can be controlled with a gate valve,while the pressure in the discharge chamber can be adjusted with a throttle valve if necessary.This arrangement facilitates plasma generation at a higher pressure within the plasma operation pressure regime[15,16],while a larger mean free path length of the reactant is produced in the cleaning chamber at lower pressure.The pressure gradient between these two chambers is helpful for the distribution of radical species across the cleaning chamber,which is compatible with the size of the optics.This ‘‘Downstream''style is shown in Fig.1.

As shown in Fig.2,the experimental apparatus includes a turbomolecular pump,backing pump,quartz crystal microbalance(QCM),vacuum gauge,plasma source,and residual gas analyzer(RGA).The high vacuum environment of the chamber is achieved through these pumps,and the mass flow controllers(MFC)not only control and display the gas flow of hydrogen and argon,but also adjust the ratio of the mixing gas.The RGA is used to detect the density of the residual gases in the chamber.The carbon removal rates and the change in carbon thickness are monitored by the QCM on the quartz wafers.lf ow of 2 sccm was introduced to ensure a gas ratio of 1:2.A vacuum chamber pressure of 1×10-3mbar was maintained by adjusting the gate valve.The carbon-coated specimen was treated with the Ar/H2plasma,as shown in Fig.3b.Finally,the carbon-coated specimen was treated with pure argon plasma at the same vacuum pressure,as shown in Fig.3c.

The temperature sensor indicated that the temperature of the sample surface changed slightly during the above process and was slightly higher than room temperature.There was no difference in temperature among the three types of gas discharge plasma,as the plasmas were all under lower pressure.As mentioned above,the chamber pressure for all three types of gas discharge was adjusted close to 0.001 mbar by the gate valve.The power was supplied identically by the GV10X at 90 W.Therefore,the procedures shown in Fig.3 were conducted under the same conditions(plasma generator,experimental apparatus,pressure,temperature,and power),and their differences lie only in the gas type and resulting plasma.

In Fig.4,the changes in the carbon thickness have been shown only under stable conditions,and the non-steady testing results have been excluded.To compare the changes in the removal rates for the three steps in Fig.3 more intuitively,both the initial carbon thickness and the start

3 Results and discussion

3.1 Comparison of removal using Ar/H2and pure gas plasmas

Fig.1(Color online)Schematic of the ‘‘Downstream''work style

Fig.2 Conceptual layout of the carbon removal apparatus(QCM quartz crystal microbalance,TV throttle valve,VG vacuum gauge,TMP turbomolecular pump,EV electro valve,BP backing pump,GV

Experiments with specimens were conducted to investigate carbon removal using an Ar/H2plasma.The removed thickness of carbon was monitored through the QCM.First,a pure hydrogen flow of 1 sccm was set by the MFC,and the plasma was ignited at a vacuum chamber pressure of 1×10-3mbar by adjusting the gate valve(equivalent to changing the pumping speed of the turbomolecular pump).The surface of the carbon-coated quartz wafer was exposed to the hydrogen plasma,as shown in Fig.3a.Next,the hydrogen flow of 1 sccm was preserved,while an argon gating valve,LV leaking valve,TS temperature sensor,MV manual valve,RGA residual gas analyzer,GDV gas dosing valve,MFC mass flow controller,GP gas puri fier,PR pressure reducer)time of the three steps have been adjusted to zero in Fig.4.It can be seen from Fig.4 that the removal rates of the pure H2plasma,pure Ar plasma,and Ar/H2plasma were 0.048 nm/min,0.09 nm/min,and 0.408 nm/min,respectively.The removal rate with the combined Ar/H2plasma is approximately four times larger than the sum of the separate plasmas at a power of 90 W with the GV10X RF gun and a total pressure of 0.001 mbar.The carbon thickness removed versus time curve clearly demonstrates the synergistic effect of the Ar/H2plasma.Compared with the removal of carbon using pure H2or Ar plasma,the ef ficiency was improved by the addition of argon to the hydrogen plasma.It is necessary to discuss the removal mechanism of the enhancement using Ar/H2plasma.The mechanism for carbon removal includes two aspects:physical sputtering and chemical erosion.

Fig.3(Color online)Photographs of RF plasma observed through a quartz window(colored):a H2plasma,b Ar/H2plasma,and c Ar plasma

3.1.1 Physical sputtering

In the mechanisms leading to the erosion of plasma,physical sputtering[17,18]is capable of removing surface atoms from a solid due to the impact of energetic particles,which results in elastic energy transfer from the incident particles to target atoms.When the energy transferred to surface atoms is below the threshold energy,Eth,the sputtering yield is zero.However,when the energy of the incident particles is greater than the threshold energy,surface atoms can be ejected.Ethis related to both the surface binding energy of carbon and the mass of the incident particles.

Fig.4(Color online)Carbon thickness removed curve versus time

Fig.5(Color online)Energy dependence of the sputtering yield and the energy thresholds of different species on carbon by the Bohdansky formula[18]

The sputtering mechanism can be described by momentum transport in a collision cascade initiated by the incident particles.This removal mechanism is mainly related to the energy carried by the particles.Physical sputtering is a well-investigated erosion mechanism for the dominant processes.The Bohdansky formula,an empirical equation based on experimental data,is widely used[19].The sputtering yields of six gases(hydrogen,argon, fluorine,oxygen,nitrogen,and helium)have been calculated using simulation software[20]based on the Bohdansky formula.As shown in Fig.5,the sputtering yield of the above particles is very low.As with nitrogen, fluoride,and oxygen,the carbon threshold energy is higher than that of argon,hydrogen,and helium.Pure Ar plasma is widely used in ion beam etching(IBE)to polish the surface of mirrors[21],but IBE is not suitable for multilayers owing to the potential for serious damage to the upper layers.As for low-pressure plasmas,no accelerating process exits,and thus the energy of the atoms is not very high(less than 300 eV)[22].However,Ar,as an inert gas,can avoid introducing unnecessary chemical products and facilitate plasma ignition.In other words,the removal rate of the pure Ar plasma in Fig.4 is mainly attributable to the sputtering effect.In contrast,however,the sputtering effect of the hydrogen plasma and Ar/H2plasma on the carbon removal is negligible,and the enhanced removal is caused by the chemical erosion mechanism.

3.1.2 Chemical erosion

Chemical erosion[23]is the formation of volatile molecules on the target surface.The interaction between species in the hydrogen plasma and the deposited carbon can be divided into two steps:hydrogenation and desorption.Generally,the deposited carbon is amorphous,and the orbital hybridization state of the carbon atoms is sp2.When the hydrogen atoms arrive at the surface,hydrogenation occurs,and the orbital hybridization state of the carbon changes from sp2to sp3[24].When hydrogenation is complete,the orbital hybridization state of carbon is transformed to sp3.When the hydrocarbon molecules accumulate enough energy from collision with the species in the plasma,they will desorb from the surface and escape into the gas.Both hydrogenation and desorption have an effect on the removal rate.

During hydrogenation,radical H atoms first adsorb on the surface and then react with carbon atoms.In a pure hydrogen plasma,the following chemical reaction can occur on the surface:

where(gas)represents atoms or molecules in the gas phase,and(ads)indicates atoms or molecules adsorbed on the surface.In the presence of the above recombination reaction,the reaction ef ficiency between the adsorbed hydrogen atoms and the deposited carbon is signi ficantly affected.

The composition of the species in the plasma is closely related to the reaction ef ficiency,and thus,it is necessary to investigate the plasma differences using diagnostic techniques.Mass spectrometry is a common plasma diagnostic technique.RGA was utilized to diagnose the different plasmas by detecting the ion current,which corresponds to the density of species.Different masses represent different types of species in the plasma.The main mass spectra of the different plasmas are shown in Fig.6.In the pure hydrogen plasma,the primary species is H+3,corresponding to a mass number of 3,which coincides with the results given in Ref.[14].However,the density of radical H atoms is very small,which is consistent with the ef ficiency of carbon removal.

Fig.6(Color online)Mass spectra of different plasmas obtained with RGA

Compared to the pure hydrogen plasma,the density of radical H atoms is increased by about one order of magnitude in the Ar/H2plasma,as shown in Fig.6.Annemie et al.[26,27]suggested that the production of radical H is enhanced in the Ar/H2plasma according to reactions(2)-(5),butparticularly through reaction (2) by the metastable Ar atom(Ar*m)due to the Penning effect.

Quench and dissociation of H2:

Charge transfer:

Recombination:

As shown in Fig.6,compared to pure H2or Ar plasma,the density of the polyatomic ArH+ion corresponding to a mass of 41 is increased signi ficantly in the Ar/H2plasma.The formation of ArH+can occur in two ways,as given below.Annemie et al.[25]determined that the ArH+ions were mainly created through reaction(6).

H-atom transfer:

Proton transfer:

Unlike physical sputtering,the transport of active particles and reaction products is the primary aspect of chemical erosion.It is believed that the polyatomic ArH+ion may transport hydrogen radicals as a gas carrier in the removal of carbon contamination.

In ion-enhanced gas-surface chemistry,Coburn and Winters[23]attributed the mechanism responsible for the Ar+-enhanced F2-Si reaction rate to adsorption and desorption.This mechanism has been widely accepted in the field of chemical kinetics and surface processes.It is believed that adsorption and desorption are very important,and in many cases,either of these reactions is the ratelimiting step for a surface process,especially at low energies[24].The hydrogen-carbon system is very similar to the fluorine-silicon system,and thus,the removal of carbon contamination by an Ar/H2plasma can be described by the following sequence:(1)non-dissociative adsorption of gas-phase species on the surface;(2)reaction between the polyatomic ion and deposited carbon atoms and formation of adsorbed product molecules;(3)recombination of the residual ions;and(4)desorption of the product molecules.These steps are illustrated schematically in Fig.7.

The enhanced removal with Ar/H2plasma is related to the steps shown in Fig.7.Chemical adsorption often occurs on the atomic clean surface,but may not occur on the same surface adsorbed with monolayer gas.The specimen was exposed to the atmosphere before removal was carried out.The gas in the air(mainly nitrogen and oxygen)was thus adsorbed on the surface of the specimen.This adsorption layer cannot be completely removed even under vacuum,but it is removed under the ionic bombardment of the Ar/H2plasma,which is helpful for the adsorption of ArH+or hydrogen atoms in the plasma.

Fig.7 Flowchart of the reaction between ArH+and deposited carbon

As mentioned above,the adsorption layer hinders the reaction of active particles with the deposited carbon.Therefore,the desorption step is important for improving the removal ef ficiency.The adsorption and desorption of particles on the surface exist in a dynamic equilibrium[28],and the conversion direction of the equilibrium is affected by the vacuum condition,temperature,and other particles.The vacuum situation and temperature of the removal process remain almost unchanged.However,as shown in Fig.7,argon ions(Ar+)promote desorption of the products and residual argon atoms.Therefore,for the arrival of active particles on the carbon surface and the removal of volatile products,argon plays a catalytic role in the species transmission.

As mentioned above,there are several approaches by which Ar/H2plasma can improve the removal rate of carbon contamination:(1)increasing the concentration of radical hydrogen atoms;(2)expediting the adsorption of hydrogen radicals on the surface of the optics;and(3)increasing the desorption of reaction products.

3.2 Optimized parameters for removal using Ar/H2 plasma

To remove carbon contamination with a higher ef ficiency using Ar/H2plasma,the optimal parameters should be determined for practical application,including the vacuum pressure,RF output power,and gas mixing ratio.

The carbon removal rates obtained with various process parameters at a feedstock gas mixing ratio of 35%H2and 65%Ar are summarized in Table 1.As the experimental data in Table 1 indicate,at different source powers,higher removal rates are obtained at a total pressure of 1×10-3mbar,while the removal rates increase with the power at different pressures.In addition,the highest rate of 0.41 nm/min is obtained at a pressure of 1×10-3mbar and RF power of 90 W.From observation of the experimental results,when the pressure is below 2×10-4mbar,it is dif ficult to produce plasma because there are fewer molecules in the plasma region to create a cascade that would strike the plasma.The pressure indicates the mean free path of species in plasma.When the pressure is decreased,the mean free path of the radicals increases.Although more radicals are produced at higher pressure,the number of radicals available for removal is increased by lowering the pressure.This is why the GV10X was designed in the‘‘Downstream''style[15,16].

The gas mixing ratio has a strong effect on the ef ficiency of the removal rate.With a chamber pressure of 1×10-3mbar,a series of experiments with different source powers and gas mixing ratios was carried out,and the results are shown in Fig.8.

Table 1 Carbon removal rates at different total pressures and source powers(with a feedstock gas mixing ratio of 35%H2and 65%Ar)

Fig.8(Color online)Carbon removal rate curves with varying gas ratio and power

The relationship between the removal rate and the power can be interpreted as the removal rate increasing with increasing power.Higher RF power means that more energy is applied to the particles.With increasing RF power,the energy of the species will increase,which will enhance the desorption of reaction products and result in an improvement in the removal rate.

However,the relationship between the removal rate and the gas mixing ratio was different.When the hydrogen proportion is less than 35%,the removal rate grows continuously with increasing proportion of hydrogen.However,when the proportion of hydrogen exceeded 35%,the reaction rate no longer increased and even decreased.The increase in the proportion of H2corresponds to a decrease in the proportion of Ar,and thus,the catalytic effect of Ar on the removal will be weakened.In addition,in the low power range(≤60 W),the gas mixing ratio has little effect on the removal rate,while in the high power range(>60 W),its effect on the removal rate is obvious.It is believed that when the power is higher than 60 W and the proportion of H2is greater than 35%,the density of the polyatomic ArH+ion will decrease because the energy of the plasma is too high.

3.3 Optimal removal on the multilayer

As in the experimental results mentioned above,the optimal removal parameters are a total pressure of 0.001 mbar,source power of 99 W(the maximum power of the GV10X),and an H2/Ar mixing ratio of 1:2.A Mo/Si multilayer on a silicon substrate is widely used to improve the re flectivity of X-rays on the beamline[29],as shown in Fig.9a.For the specimen,a Mo/Si multilayer was coated with amorphous carbon with a thickness of 40 nm,as shown in Fig.9c.The optimal carbon removal process was performed on the carbon-coated Mo/Si multilayer with half of the specimen shielded,as shown in Fig.9b.The carbon removal process was performed on two carbon-coated specimens using processing times of 100 min and 60 min.As shown in Fig.10,the near-normal incident re flectivity of the specimens was detected using an X-ray spectrometer.The results show that compared to the Mo/Si multilayer,the re flectivity of the carbon-coated specimen decreased by about 22.5%.After 100 min of processing,the re flectivity of the specimen is close to that of the pure multilayer films,while the re flectivity of the shielded part is close to that of the carbon-coated multilayer.If the processing time is not adequate,e.g.,60 min,the re flectivity of the specimen exposed to the plasma is only partially recovered.This is consistentwith previous experimental results using quartz wafers.Under the optimal removal process,for a carbon layer with a thickness of 40 nm,at least 100 min is required at the removal rate of about 0.4 nm/min.

4 Conclusion

The enhanced removal process of X-ray-induced carbon contamination using RF Ar/H2plasma was experimentally investigated in this study.The enhanced carbon removal using Ar/H2plasma occurs in the following ways:(1)increasing the concentration of radical hydrogen atoms;(2)expediting the adsorption of hydrogen radicals on the surface of the optics;and(3)increasing the desorption of the reaction products.The optimal removal parameters using Ar/H2plasma were determined experimentally.Theoptimal removal process was performed on a carboncoated Mo/Si multilayer,and the re flectivity was successfully recovered by removing the carbon contamination.This approach is feasible for use in synchrotron radiation beamlines,X-ray free-electron laser facilities,and even extreme ultraviolet lithography.Further efforts will focus on the realization of in situ carbon removal.

Fig.9 Carbon-coated Mo/Si multilayer treated with Ar/H2 plasma

Fig.10(Color online)Re flectivity of a carbon-coated Mo/Si multilayer with Ar/H2plasma treatment