APP下载

Improved formation density measurement using controllable D-D neutron source and its lithological correction for porosity prediction

2022-02-23LiZhangHuaWeiYuYangLiWenBaoJiaXiaoHanXueSenGeng

Nuclear Science and Techniques 2022年1期

Li Zhang • Hua-Wei Yu • Yang Li • Wen-Bao Jia • Xiao Han • Xue-Sen Geng

Abstract Controllable D-D neutron sources have a long service life,low cost,and non-radioactivity.There are favorable prospects for its application in geophysical well logging,since traditional chemical radioactive sources used for well logging pose potential threats to the safety of the human body and environment.This paper presents an improved method to measure formation density that employs a D-D neutron source.In addition,the lithological effect on the measured density was removed to better estimate the formation porosity.First,we investigated the spatial distribution of capture gamma rays through Monte Carlo simulations as well as the relationship between the ratio of capture gamma ray counts and formation density to establish theoretical support for the design of density logging tools and their corresponding data processing methods.Second,we obtained the far to near detector counts of captured gamma rays for an optimized tool structure and then established its correlation with the density and porosity of three typical formations with pure quartz,calcite,and dolomite minerals.Third,we determined the values for correcting the densities of sandstone and dolomite with the same porosity using limestone data as the reference and established the equations for calculating the correction values,which lays a solid foundation for accurately calculating formation porosity.We observed that the capture gamma ray counts first increased then decreased and varied in different formations;this was especially observed in high-porosity formations.Under the same lithologic conditions (rock matrix),as the porosity increases,the peak value of gamma ray counts moves toward the neutron source.At different detector-source distances,the ratio of the capture gamma ray counts was well correlated with the formation density.An equation of the formation density conversion was established based on the ratio of capture gamma ray counts at the detector-source distances of 30 cm and 65 cm,and the calculated values were consistent with the true values.After correction,the formation density was highly consistent with the true value of the limestone density,and the mean absolute error was 0.013 g/cm3.The calculated porosity values were very close to the true values,and the mean relative error was 2.33%,highlighting the accuracy of the proposed method.These findings provide a new method for developing D-D neutron source logging tools and their well-log data processing methods.

Keywords Density measurement · D-D neutron source ·Lithological correction · Porosity prediction

1 Introduction

Density logging is an effective method for porosity determination and lithology indication.With the development of geophysical prospecting for fossil fuels,density logging theories and methods have become increasingly necessary in recent years [1,2].In particular,the promotion of health safety and environmental awareness has necessitated the use of different sources in density logging[3-5].Some research institutions and scholars both in China and abroad have conducted research on the replacement of chemical sources with D-T neutron [6-8]and X-ray sources [9,10] in density logging,and progress has been made in the establishment of density measurement and correction methods[11-13].D-D neutron sources are superior to D-T neutron sources;they have the advantages of a long service life,low cost,and non-radioactivity [14,15].However,the neutron yield of D-D neutron sources is relatively low,which restricts their development [16,17].In recent years,with the increase in the neutron yield of D-D sources,their application in well logging has attracted more attention[18,19].D-D-neutron sources can produce high thermal neutron fluxes by interacting with a formation.They are usually directly used in neutron porosity logging [20-22],but their application in density logging is still in the exploration stage.He et al.analyzed the energy spectra ofγ-rays generated by the interaction between a D-D neutron source and a formation and found that the spectra of the capturedγ-rays and mixed fieldγ-rays were well correlated with the formation density[23].Zhang Li studied the feasibility of the use of D-D neutron sources in density logging and factors affecting the spatial distribution of the induced gamma rays [24,25].Some Chinese companies and institutes,such as China Oilfield Services Limited,carried out studies on density logging with a controllable D-D neutron source and pointed out that the spatial distribution of the inducedγ-rays had a significant impact on the design of logging tools[26].In the previous studies,the feasibility of density measurement with a controllable D-D neutron source was verified,but the detailed methods for density calculation and correction were not given.

Based on previous studies,this study proposes a method for measuring formation density with a D-D neutron source and correcting the effects of lithology.The Monte Carlo N Particle Transport Code (MCNP) was used to study the characteristics of the spatial distribution of the captured gamma rays in formations of varying lithology.The code was also used to analyze the relationship between the ratio of gamma ray counts and formation density at different detector-source distances and to establish equations for calculating formation density.Finally,using the limestone data as a reference,density correction values under varying porosity conditions were determined,which laid a solid foundation for accurate porosity calculations.This study provides a reference for the development of controllable D-D neutron source density logging tools and research on their application.

2 Theoretical background

During D-D source density logging,the pulsed neutron generator (nuclear reaction formula:d+2H →3H+n)generates 2.45 MeV fast neutrons,which react with the nuclides in the formation.The γ-rays generated during these reactions are used as the inducedγ-ray source to measure the density of the formation.It has been verified that the inducedγ-rays are mainly captureγ-rays.Unlike the point sourceγ-rays used in traditional density logging,captureγ-rays are not single energy rays,and their spatial positions are not fixed.The photons of these spatially distributed captureγ-rays form theγ-ray source for density logging.Captureγ-rays are attenuated after they are generated.Theγ-ray flux measured by the detectors can be calculated as follows [27,28]:

whereφtis the neutron flux,μis the γ-ray mass attenuation coefficient,andρbis the bulk density of the formation.

Equation (1) indicates that the responses of captureγrays detected by the detectors are related to the macroscopic capture cross section of the formation,the distribution of thermal neutrons,and formation density.Therefore,the ratio of capture gamma ray counts measured by gamma-ray detectors may vary even in formations with the same density.This is mainly because the capture gamma ray counts are affected by both the macroscopic capture cross section of the formation and the spatial distribution of thermal neutrons.Figure 1 shows the distribution of capture gamma ray fluxes in three formations(sandstone,limestone,and dolomite)with the same density(ρ=2·65 g/cm3).The intensity of the capture gamma ray flux is highlighted in colors (high values in red,and low values in blue).

As shown in Fig.1,in the three formations with the same density,the gamma rays are spatially distributed in different patterns in the zones around the neutron source.In particular,the capture gamma ray flux varies significantly near the detector that was far from the neutron source,demonstrated by the different distributions and ranges of colors in the blue area,as shown in the right panels of Fig.1.The capture gamma ray flux was the lowest in the dolomite formation and the highest in the sandstone formation.When a gamma ray count measured by a single detector is used to determine the formation density,the density measurements have significant errors.

Fig.1 (Color online) Distributions of capture gamma ray flux in three formations (sandstone,limestone and dolomite) with the same density

To eliminate the effects of other factors on the density measurement,the ratio of captureγ-ray counts measured by two detectors(near and far detectors) was used to measure the formation density.The relationship between the ratio of captureγ-ray counts measured by the near and far detectors,expressed asR,and the formation density can be obtained using Eq.(1):

whereγ1andγ2are the distances from the near and far detectors to the neutron source,respectively,andφt1andφt2denote the neutron flux measured by the near and far defectors,respectively.Ris mainly related to the formation density,but it is also affected by the spatial distribution of neutrons.This study mainly investigates the calculation of the density using the ratio of gamma-ray counts measured by the two detectors.

In nuclear logging,the Monte Carlo method is a commonly used method for studying the reaction process and spatial distribution of particles.MCNP is a general Monte Carlo particle transport code that can be used for the transport of various particles,such as neutrons,photons,and electrons [29,30].In this study,this method was used to study the characteristics of the spatial distribution of capture gamma rays under various formation conditions.We built a pure theoretical model (not considering wellbore and logging instruments)as shown in Fig.2,which is a sphere and is divided into a number of concentric spheres with a radius difference of 5 cm.The initial radius (detector-source distance) isr=5 cm,and the radius of the outermost sphere isr=120 cm.The neutron source is located at pointO,the center of the sphere.Neutrons are directly emitted in the formation.The gamma ray fluxes through the spherical surfaces are recorded.The neutron yield of the D-D neutron generator is 1×107n/s,and the intensity of neutron source is 2.45 MeV.

Fig.2 (Color online) Calculation model

Three typical formations,namely sandstone,limestone,and dolomite,were used for the simulation.The rock matrices of these formations were SiO2,CaCO3,and CaMg(CO3)2,respectively.The pore fluid,porosity,and porosity variation steps 2% were H2O,0-40%,and 2%.Detailed parameters are listed in Table 1.

The calculation model shown in Fig.2 was used to record the gamma-ray fluxes through the spherical surfaces under various formation conditions (as listed in Table 1).The gamma-ray counts at different detector-source distances were obtained.The results are shown in Fig.3.

Table 1 Parameter information of three typical lithologic strata

Figure shows that as the detector-source distance increases,the gamma ray count increases then decreases,but its distribution range is affected by porosity.For pure minerals with a porosity of zero,the capture gamma rays had a wide spatial distribution range.As the porosity increased,the spatial distribution range narrowed,and the peak value of the gamma ray count moved toward the neutron source.When the porosity was 40%,the peak value was closest to the neutron source.The main reasonfor this is that water is used as the pore fluid for the numerical simulation.A high porosity indicates a high hydrogen content.The neutrons slowed down quickly.Because there are more thermal neutrons in the zone close to the neutron source,the gamma ray count resulting from thermal neutron capture is high.It should be noted that thermal neutron counts,such as carbon,silicon,and magnesium,are also affected by other elements in the formation.In low-porosity formations,the effects of these elements are not negligible.In pure rock masses,the neutrons slow down over a long time.Hence,when neutrons slow down to become thermal neutrons,they will be far away from the neutron source.Therefore,the peak value of the capture gamma ray count will also be far away from the neutron source.The pattern of the spatial distribution of the capture gamma rays varies in different formations.This is closely related to the elements in the rock matrices of different formations.

3 Relationship between the ratio of capture gamma ray counts and formation density

The gamma ray counts measured in different formations at different detector-source distances were analyzed to obtain the optimal ratio of the gamma ray counts measured by the near and far detectors for calculating the density.As shown in Fig.3,the peak values of the captured γ-ray counts in different formations were mainly distributed within the range of 20-80 cm.The locations of the peak values represent the main distribution zones of the capture gamma.The relationship between the ratio of the capture gamma ray counts and formation density was analyzed by fitting at different detector-source distances.The results listed in Table 2 show that for formations with the same lithology,the ratio of capture gamma ray counts was highly correlated with the formation density,and the average correlation coefficient was 0.99.

Fig.3 (Color online) Distribution of capture gamma rays in three different lithologic strata with different source distances: a.Sandstone formation, b.Limestone formation, c Dolomite formation

The above analysis shows that in the main gamma capture spatial distribution area between 20 and 80 cm,the gamma count ratio under different source distance combinations had a good correlation with the formation density,especially when the near-source distance was 25-35 cm and the far-source distance was 50-70 cm.In addition,the size of the actual instrument must be also considered,including the detector size and thickness of the shield,and the distances of the near and far sources were selected as 30 cm and 65 cm after comparison.Based on the structural design of the logging instrument,a structural model was developed.The model is shown in Fig.4.The detailed parameters of the model are summarized below.The wellbore had a diameter of 20 cm and was filled with fresh water.The neutron yield of the D-D neutron source was 2×107n/s,and the pulse width was 40 μs.Two NaI-type gamma-ray detectors were used.The near and far gamma ray detector were 30 and 60 cm away from the D-D neutron source,respectively.The lengths of the near and far detectors were 5 and 10 cm,respectively.Shields were placed between the neutron source and detectors and between the near detector and far detector.These shields were made of tungsten,iron,and nickel materials with a density of 17.78 g/cm3.

Using the model shown in Fig.4,the ratios of gamma ray counts measured by the near and far detectors in sandstone,limestone,and dolomite formations with varying porosity (the parameters of these formations are listed in Table 1) were obtained,and the relationship between the ratio of gamma ray counts and formation density was analyzed,as shown in Fig.5.

Fig.4 (Color online)Schematic diagram of instrument model

Table 2 Correlation coefficient of the counting ratio and formation density under 42 different source distance combinations

The equations for calculating the density of these three formations were found to be

wherexcis the capture gamma count ratio between the near and far detectors,andydis the formation density.

From Fig.5 and Eqs.3-5,it can be seen that in the three formations,the relationship between the ratio of gamma ray counts and formation density follows functions.As the ratio of gamma ray counts increased,the formation densitydecreased,and the ratio of gamma-ray counts was affected by the formation porosity.Furthermore,the gamma ray counts measured by the near and far detectors were high for greater porosity.This is because the hydrogen content of the formation increases with increasing porosity,which slows neutrons quicker,increasing the thermal neutron flux close to the near detector and number of gamma rays from thermal neutron capture.On the other hand,the gamma ray count measured by the far detector decreased with greater porosity accordingly.Therefore,the ratio of gamma ray counts measured by the near and far detectors increases.In the three formations,the ratio of gamma ray counts has a good fit with the formation density,but the effects of lithology are significant.To obtain accurate information on the formation density through density logging,the effects of lithology must be corrected.

Fig.5 (Color online) Relationship between the capture gamma ray count ratio and formation density for the source distance combination of 30/65 cm

4 Method for correcting the effects of lithology

Formation density data are frequently used in geophysical prospecting to obtain porosity.However,it is very difficult to precisely transform the density data to the porosity because the density is strongly affected by mineral composition.The inaccuracies of matrix density will have a significant impact on the calculated porosity.To determine the porosity of formations accurately,it is usually necessary to convert the density logs to values relative to a certain standard lithology in order to eliminate the impact of inappropriately selected matrix parameters on the calculation results.

First,the densities of sandstone,limestone,and dolomite formations with varying porosities were calculated using the equations for calculating the formation density.Second,the values for correcting the effects of lithology on the densities of the three formations for varying porosities were calculated.The results are shown in Table 3.

From Table 3,it can be seen that for formations with varying porosity,different values should be used to correct the effects of lithology on density.The calculated density of the sandstone formation was slightly higher than the true value,and that of the dolomite formation was slightly lower than the true value.Therefore,the value for correcting the effects of lithology in the sandstone formation is negative,and that for correcting the effects of lithology in the dolomite formation is positive.The relationship between the porosity values of these three formations and the corresponding correction values was analyzed,as shown in Fig.6.The fit equations are as follows:

Table 3 Three lithologic and stratigraphic density corrections

wherexpis the porosity,andΔydis the density correction value.

From Fig.6,it can be seen that for the three formations,the value of the density correction is well correlated with the porosity.The density correction value of the limestone formation was the smallest,which is a result of statistical errors.The density correction value of the dolomite formation was large.When the porosity was lower than 40%,this value was equal to or smaller than 0.16 g/cm3.The density correction value of the sandstone formation was moderate.As the porosity increased,this value decreased,and when the porosity was 40%,it was 0.0122 g/cm3.Using the density correction values of the three formations,the formation porosity can be accurately calculated to quantitively determine the formation parameters.

Fig.6 (Color online) Density corrections for sandstone,limestone,and dolomite for different porosity

To validate the accuracy of the density measurements and corrections of the lithology effect on porosity,the densities and porosities of sandstone,limestone,and dolomite formations (the pore fluid is water) with porosities of 3%,5%,13%,15%,23%,25%,33%,and 35%were calculated using the Monte Carlo numerical simulation and the model shown in Fig.4.The calculated values were compared with theoretical values.The results are shown in Figs.7 and 8,respectively.

Figure 7 shows that almost all the density values calculated with the density calculation equations fall on the 45° line,and these calculated values are highly consistent with the true values,which verifies the accuracy of the equations.Lithology has a significant impact on the calculated density values,and the density measurement errors affect the porosity calculation.

Figure 8 shows the comparison of the porosity values of the sandstone and dolomite formations calculated before and after the effects of lithology were corrected.In Fig.8,the porosity values of the sandstone and dolomiteformations calculated before correction are distributed on both sides of the 45° line,and the data points of the dolomite formation are farther from this line.After corrections are made,the calculated values of porosity are highly consistent with the true values and most fall on the 45° line.Figure 9 shows the relative errors of the calculated porosity values of the sandstone and dolomite formations.In Fig.9,when porosity is less than 5%,the relative errors are significant but smaller than 5%.Only the relative error of the calculated porosity of sandstone reaches 30%,which is related to the cumulative error in the density measurement.When porosity is higher than 5%,the relative errors in the calculated porosity values smaller than 4%,indicating that the correction method is effective.The formation porosity parameters obtained during density measurements with a D-D neutron source indicate that the effects of lithology are not negligible,and they are greater in low-porosity formations.Therefore,the effects of lithology must be corrected to obtain accurate formation parameters.

Fig.7 (Color online) The relationship between the calculated and true density values is obtained using the density fitting formula

Fig.8 (Color online) Comparison of the calculated and true porosity values before and after correction:(a) Sandstone,(b) Dolomite

Fig.9 (Color online)Relative error of the calculated porosity before and after correction

5 Conclusion

In density measurements with a D-D neutron source,lithology has a significant impact on the spatial distribution of capture gamma rays.In formations with the same lithology,the spatial distribution of capture gamma rays follows certain rules.In formations with varying lithologies,the spatial distribution of capture gamma rays varies significantly.Through an analysis using a neutron sourceformation model,it was found that when porosity is within the range of 0-40%,the capture gamma rays in the three typical formations are mainly distributed within the range of 20-80 cm away from the neutron source.

The ratio of gamma ray counts measured by two gamma-ray detectors can be used to determine the formation density.The ratio of capture gamma ray counts was highly correlated with the formation density,and the correlation coefficient was 0.99.However,the density measurement was affected by the lithology.For formations with varying lithologies,different equations were used to calculate the density.

The accuracy of the equations for calculating the formation density and correcting the effects of lithology on porosity was verified using the simulation data.The mean error of the density values obtained from the density calculation equations was smaller than 0.015 g/cm3,which satisfies the density measurement requirements.After the effects of lithology were corrected,the mean relative errors of the calculated formation porosity were smaller than 4%.This shows that the proposed correction method can effectively reduce the effects of lithology on the porosity calculation and improve the accuracy of the formation parameters.

Author contributionsAll authors contributed to the study conception and design.Material preparation,data collection and analysis were performed by Li Zhang,Hua-Wei Yu,Yang Li,Wen-Bao Jia,Xiao Han,Xue-Sen Geng.The first draft of the manuscript was written by Li Zhang and all authors commented on previous versions of the manuscript.All authors read and approved the final manuscript.