APP下载

Magnetic Array Assisted Triboelectric Nanogenerator Sensor for Real‑Time Gesture Interaction

2021-03-08KenQinChenChenXianjiePuQianTangWencongHeYikeLiuQixuanZengGuanlinLiuHengyuGuoChenguoHu

Nano-Micro Letters 2021年3期

Ken Qin, Chen Chen, Xianjie Pu , Qian Tang , Wencong He, Yike Liu, Qixuan Zeng, Guanlin Liu, Hengyu Guo, Chenguo Hu

ABSTRACT In human‑machine interaction, robotic hands are useful in many scenarios. To operate robotic hands via gestures instead of handles will greatly improve the convenience and intuition of human‑machine interaction. Here, we present a mag‑netic array assisted sliding triboelectric sensor for achieving a real‑time gesture interaction between a human hand and robotic hand. With a finger’s trac‑tion movement of flexion or extension, the sensor can induce positive/negative pulse signals. Through counting the pulses in unit time, the degree, speed, and direction of finger motion can be judged in real‑time. The magnetic array plays an important role in generating the quantifiable pulses. The designed two parts of magnetic array can transform sliding motion into contact‑separation and constrain the sliding pathway, respectively, thus improve the durability, low speed signal amplitude, and stability of the system. This direct quantization approach and optimization of wearable gesture sensor provide a new strategy for achieving a natural, intuitive, and real‑time human‑robotic interaction.

KEYWORDS Sliding triboelectric sensor; Magnetic array; Gesture; Real‑time; Human‑machine interaction

1 Introduction

Intuitive human‑machine interaction (HMI) plays more and more an important role in duties and daily life. From tradi‑tional keyboards to various touchpad nowadays, HMIs have been developed to be more natural [1], integrated [2], port‑able [3, 4], and even wearable [5, 6]. For the skillful robotic hand in industry, military service, surgery, or entertainment, traditional interaction method based on handles cannot meet current requirements [7, 8]. A wearable gesture sensor that can perceive the dexterous movement of each finger will fulfil this need [9-12]. The emergent triboelectric nano‑generator (TENG) exhibits great potential as an alterna‑tive scheme in some fields, including physiological signal collection [13, 14], mechanical signal detecting [15, 16], and visual tracking [8, 17]. Based on the coupling of tribo‑electrification and electrostatic induction, TENG has been applied in energy harvesting [18, 25, 26] and self‑powered mechanical sensing [1, 19-24]. However, most studies in gesture sensing based on TENG take signal amplitude as feature to represent finger’s once time movement and ignore the intermediate process [13, 14, 16]. Moreover, to quan‑tify the bending degree via signal amplitude is unstable, because there are too many factors affecting the amplitude. Therefore, a finger‑wearable TENG sensor for quantifying the finger’s bending/straightening for a real‑time gesture interaction is expected [15, 27].

In this work, we present a magnetic array assisted sliding triboelectric sensor (Ma‑s‑TS) to achieve a real‑time ges‑ture interaction between a human hand and robotic hand. During the bending of the finger, as shown in Fig. S1, the rotation angle is proportional to the tensile displacement at the joint (as the fulcrum). Therefore, We can judge the bend‑ing degree by the sliding displacement. The basic sensing principle of Ma‑s‑TS is to induce positive/negative pulses under the finger traction movement (flexion/extension), and then by counting the pulses in unit time, to sense the degree, speed and direction of a finger motion in real‑time. It is a creative design that the magnetic array assisted sliding structure can constrain the sliding pathway and translate the sliding motion into contact‑separation, and thus can improve the stability, durability and low speed signal amplitude. This work brings an optimized scheme for real‑time gesture inter‑action based on a wearable TENG sensor, and it promises a widespread application of intuitive, natural HMIs.

2 Methods

2.1 Fabrication of Ma‑s‑TS

Typically, the Ma‑s‑TS was fabricated as two main parts, stator and slider. The stator (20 × 12 mm2) was made up of an electrode layer (thickness: 0.01 mm) sandwiched between upper layer of polytetrafluoroethylene (PTFE) film (thickness: 0.08 mm) and bottom layer of flexible halbach magnetic arrays made of strontium ferrite magnetic pow‑der and rubber (thickness: 0.315 mm), which was pasted on an acrylic board. The slider (length: 10 mm, width: 20 mm) was a Y‑shaped PET strip, which covered a layer of flexible rubber and a layer of halbach magnetic arrays. Finally, a copper layer (0.02 mm) was pasted on the surface of the as‑fabricated flexible rubber as the positive tribo‑material by polyimide tape. It should be noted that both the magnetic rubbers on the stator and slider were divided into two parts (part I and part II). The magnetic array of part I is perpendicular to the sliding direction, while that of Part II is parallel to the sliding direction, by which the two tribo‑layers were alternately pushed up and down in sliding process.

2.2 Characterization and Measurement

For electric signal test of the Ma‑s‑TS, a home‑made hinge component [15] was fabricated to simulate the fin‑ger’s motion. A numerical controlled electric stepping motor was adopted to operate the Ma‑s‑TS. An electrom‑eter (Keithley 6514) was used to measure the voltage signal. NI USB‑6356 (National Instruments Corporation) was used for multi‑channel data collection. The software was constructed on LabVIEW platform for real‑time data acquisition, analysis and control. A commercial robotic hand (LOBOT uhand, Shenzhen Hiwonder Technol‑ogy Co., Ltd.) was adopted in the real‑time interaction system.

3 Results and Discussion

Fig. 1 Structure of the Ma‑s‑TS. a Schematic diagram and multilayer structure of the Ma‑s‑TS. The insets: developing photograph of the magnetic array on the substrate and slider. b Overall structure dia‑gram. c Magnetic array assisted contact‑separation state (top and bot‑tom). d Photograph of an as‑fabricated sensor (scale bar: 1 cm)

The structure follows a sliding mode as illustrated in Fig. 1. Figure 1a presents the structural scheme of the Ma‑s‑TS, which consists of an acrylic rectangular cavity and a slider. The multilayer structure from bottom to top is the acrylic substrate, the magnetic stripe distributed in two vertical directions (part I and part II) in plane, the copper electrode divided into two parts, and the polytetrafluoroethylene (PTFE) surface. The slider also consists of two parts, which from bottom to top is the copper layer and the magnetic stripe distributed in same direction with the stator on each part. The insets show the developing photograph of the mag‑netic array on the substrate and slider. Left part forms an attractive track for stable sliding, while the right part forms the attraction-repulsion of magnetic pole in sliding. The operating principle is described later in Fig. 2. Figure 1b shows the overall structure diagram. Figure 1c shows the contact‑separation state of the right part of slider and the stator in sliding process. In this process, the left part of slider is always in attraction state to the stator to form a stable slid‑ing track. Figure 1d shows the as‑fabricated Ma‑s‑TS. The detailed fabrication process is presented in the Experimental Section.

The operating mechanism of the Ma‑s‑TS is illustrated in Fig. 2. Firstly, electrons transfer from the electrode layer to the FEP film owing to the different triboelectric polarities. And then, for part A, the slider separates from the stator under the repulsive force of the magnetic field when their magnetic properties are identical. Keeping sliding, the slider contacts with the stator under the attraction when their mag‑netic properties are different. At the same time, for part B, the slider is always attracted to the stator and slides along a straight line due to the magnetic pull. Thus, as shown in Fig. 2a, b, the alternating electric signals from the paired double electrodes in contact‑separation state are a series of periodic narrow pulses in part A. For part B, the electrode in free‑standing mode generates alternating wide‑pulse signals in a sliding cycle. These two kinds of signals are coupled to form a series of positive/negative pulses representing the fin‑ger’s flexion/extension. To interpret the working principle, the potential distribution of part A electrode (top, Fig. 2c) and part B electrode (bottom, Fig. 2c) under open‑circuit condition is simulated by COMSOL in four phases of an ordinary cycle. The actual measured open‑circuit voltage of part A and part B and that of the coupled circuit can be referred to Fig. S2. Furthermore, corresponding to Fig. 2b, the load voltage signals out of part A and part B are individ‑ually measured to verify the working principle. Figure 2d-f shows the real signals detected from the two independent parts and the coupled circuit.

To quantitatively characterize the performance of the Ma‑s‑TS, a numerical controlled electric stepping motor is used to drive a hinge component to operate it [15]. To dem‑onstrate the pulse number representing the finger’s flexion/extension degree, the stepping motor is set to rotate through different angles (54°, 72°, and 90°) at a rotation speed of 0.375 rps. Meanwhile, the sequences of pulses generated by the Ma‑s‑TS are recorded, as illustrated in Fig. 3a-c, respec‑tively. The generated pulse number is linear to the rotation angle. Therefore, the pulse number represents the finger’s flexion/extension degree. To investigate the influence of rotation speed, the stepping motor is set to rotate through 90° at different rotation speed (0.375, 0.50, and 0.625 rps). From Fig. 3d-f, it can be found that the total pulse number is a constant at the same rotation degree, which means through counting the pulse number the finger’s flexion/extension degree can be judged stably/accurately. In addition, through calculating the number of pulses per unit time, the motion speed can also be determined. The influence of the thickness to sensing accuracy is also tested in Fig. S3, because differ‑ent thickness of magnetic stripe has different number of pole pairs. Meanwhile, the relationship between driving force and thickness also be explored in Fig. S4.

Fig.2 Operating-principle of the Ma-s-TS. a Schematics of electron transfer process in the sliding. b Schematics of output signal in process. c COSMOL simulation of potential distribution under various states in sliding process. d–f Test output signal corresponding to Fig. 2b

Fig. 3 Characterization of the basic performance of Ma‑s‑TS. a–c Pulses produced from a Ma‑s‑TS when rotate through different angles (54°, 72°, and 90°) at rotation speed of 0.375 rps. d–f The pulses generated from a Ma‑s‑TS when rotate through 90° at different rotation speed (0.375, 0.50, and 0.625 rps)

The output signal is a coupled signal of two parts of elec‑trode. Therefore, the area ratio of the two parts will affect the character of the output signal, hence further affect the back‑end interaction. The detailed features are studied as shown in Fig. 4. Figure 4a illustrates the area adjustment diagram of the copper electrode of part A and part B, which corresponds to narrow pulses and wide pulses, respectively. According to the test data, as shown in Fig. 4b, when area ratio of part B to part A increases, the motion speed response range shifts left. To further understand this feature, the test data of an area ratio of 0.8 is illustrated in Fig. 4c. Figure 4d-f is the enlarged signals of Fig. 4c at a low, medium, and high rota‑tion speed for a better understanding. From rotation speed of 0.25-1.75 rps, when the slider moves slowly, the positive/negative narrow pulses are almost evenly distributed beside baseline and not be biased by the wide pulse from part B, hence hard to be distinguished (as shown in Fig. 4d). When the slider moves fast, the positive/negative narrow pulses are excessively biased by the wide pulse from part B and are hardly distinguished (as shown in Fig. 4f). For different response range requirements, in the state of slow sliding, a bigger area ratio of part B to part A helps getting a bigger bias (left shifts, Fig. 4b); while in the state of fast sliding, a smaller area ratio of part B to part A helps getting a smaller bias (right shifts, Fig. 4b). An ideal state in Fig. 4e shows that the best response range of the area ratio of 0.8 is around 1.0 rps. Therefore, it is necessary to choose the area ratio of the two parts of Ma‑s‑TS according to the speed response range requirements in different applications.

Fig. 4 Matching of two coupled parts of the slider. a Area adjustment diagram of the two parts. b Speed response range under different area ratio of part B to part A. c Test signals at rotation speed from 0.25 to 1.75 rps under area ratio of 0.8. d–f Enlarged signal of Fig. 4c at rotation speed of 0.25, 1.00, and 1.75 rps

Based on the features of the Ma‑s‑TS above, a real‑time gesture interaction system is demonstrated as shown in Fig. 5. Figure 5a shows the Ma‑s‑TS worn on the fingers. In Fig. 5b, the positive/negative pulses represent extending and bending of fingers, respectively. The phases of the human‑robotic hand corresponding to the mark numbers in Fig. 5b are demonstrated in Fig. 5c. The motion of the robotic finger is totally/completely synchronous to the motion of human fingers in real‑time. A real‑time multi‑directional continuous control of the robotic hand is demonstrated in Video S1. In this demonstrations, the real‑time control can recover at any breakpoint in finger’s flexion/extension process. Besides, Ma‑s‑TS also showed good stability in multichannel control. When some fingers bend, the other fingers are often driven unconsciously. And the unconscious movement will always produce a wrong cross talk signal. As demonstrated in Video S2, Ma‑s‑TS can suppressed the cross talk between differ‑ent channels effectively, benefitting from restriction of mag‑netic force to slider. Here, the cross talk between channels of the Ma‑s‑TS (Fig. 5e) is compared with previous joint motion triboelectric quantization sensor (Fig. 5d) [15]. The Ma‑s‑TS is more stable and thus the cross talk caused by finger linkage is suppressed, which is very important for achieving a stable real‑time gesture interaction. Futhermore, the durability of Ma‑s‑TS also has been tested in Fig. S5. After 6,200 operation cycle (at the working frequency of 0.5 Hz), the result shows that the normalized output declines to 84.6% due to intermittent contact. Besides, the output signal of previous work produced continuous narrow pulse signals based on the freestanding model is greatly affected after working for a long time. Hence, we also compared the durability of part A with previous work, as shown in Fig. S5b.

Fig. 5 Real‑time gesture interaction demonstration. a Ma‑s‑TS worn on the fingers. b Positive and negative pulses represent straightening and bending of finger. c Real‑time gesture interaction of robotic hand and human hand based on the signal of Fig. 5b. d–e Comparison with jmTQS [15] on cross talk between channels (d jmTQS, e Ma‑s‑TS)

4 Conclusions

In summary, a magnetic array assisted sliding triboelectric sensor has been proposed for achieving a real‑time gesture interaction between a human hand and robotic hand. Through counting the positive/negative pulses that represent extend‑ing and bending of fingers, respectively, the degree, speed and direction of the fingers’ flexion/extension can be judged. Besides, the magnetic array assisted sliding structure con‑strains the sliding direction and translates the sliding motion into contact‑separation, which greatly improve the stability, durability and low‑speed signal amplitude. Based on these novelties, a real‑time gesture interaction system has been established. Furthermore, this Ma‑s‑TS can be applied in other similar joint’s motion detection for a more natural, high‑preci‑sion and real‑time synchronous human‑machine interaction.

AcknowledgementsThis work was supported by National Natural Science Foundation of China (51902035 and 52073037), Natural Science Foundation of Chongqing (cstc2020jcyj‑msxmX0807), the Fundamental Research Funds for the Central Universities (2020CDJ‑LHSS‑001 and 2019CDXZWL001) and Chongqing graduate tutor team construction project (ydstd1832).

Compliance with Ethical Standards

Conflict of interestAuthors declare that they have no conflict of in‑terest.

Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Com‑mons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Com‑mons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creat iveco mmons.org/licen ses/by/4.0/.

Supplementary informationThe online version contains supplementary material at (doi:https://doi.org/10.1007/s4082 0‑020‑00575‑2).