APP下载

Development and performance characterization of a compact plasma focus based portable fast neutron generator

2020-11-10RishiVERMAEkanshMISHRAProsenjitDHANGBasantaKumarDASManrajMEENALakshmanRONGALIandArchanaSHARMA

Plasma Science and Technology 2020年11期

Rishi VERMA,Ekansh MISHRA,Prosenjit DHANG,Basanta Kumar DAS,Manraj MEENA,Lakshman RONGALI and Archana SHARMA

1 Pulsed Power & Electromagnetics Division,Bhabha Atomic Research Centre Facility,Atchutapuram,Vishakhapatnam 531011,India

2 Homi Bhabha National Institute,Anushaktinagar,Mumbai 400094,India

3 Raja Ramanna Centre for Advanced Technology,Rajendra Nagar,Indore 452013,India

4 Variable Energy Cyclotron Centre,Bidhannagar,Kolkata 700064,India

Abstract

Keywords:plasma focus,neutrons,time of flight,pinch current,peak current,plasma pinch,pseudospark switch

1.Introduction

Dense plasma focus(DPF)is the simplest and least expensive source for producing a burst of neutrons in the short duration of a few tens of nanoseconds depending on the driver energy and other device parameters.For the purpose of neutron production,it is fueled either with pure deuterium(D2)or a deuterium-tritium(DT)gas mixture[1].The typical energy generated neutrons are ~2.45 MeV with pure D2filling and~14.1 MeV with DT filling.This device was independently discovered by Mather[2]and Filippov[3]in the last century.A plasma focus(PF)tube mainly comprises a pair of coaxial electrode structures located inside the chamber that is filled with D2/DT gas at low pressure.The anode at the centre is partially covered with a coaxial insulator near the back wall,and it is surrounded with squirrel-cage cathode rods in the outer periphery.By discharging capacitor bank energy through a fast closing switch,the plasma sheath is formed in betwee⇀n the⇀ electrodes and it is lifted upwards due to Lorentz forceJr×Bθ.After reaching the anode the top plasma sheath then starts imploding along the axis with a typical velocity of~105m s−1while compressing and heating a small volume of gas that reaches densities of ≈1025m−3and temperatures of about ≈1 keV[4].Coinciding with the disruption of this hot and dense pinched plasma column due to rapid growth of magneto-hydrodynamic(MHD)instabilities,a burst of neutron is produced[5].According to the beam-target hypothesis[6],a high voltage is generated due to fast disruption of the pinched plasma and this accelerates deuterons as a consequence of diode action.The interaction of these accelerated deuterons with hot dense plasma results in the production of neutrons.

Presently,owing to spin-offs from the Neutron Activation Analysis(NAA)application[7-10],there is a consistently growing demand for cost effective,compact and energy efficient,standalone and transportable types of neutron generators.In this context,our newly developed system satisfies the aforementioned requirements to a large extent.In the category of compact standalone pulsed power system(having single capacitor and switch)based DPF devices that have been developed across the globe[11,12],this new system poses much lower inductance and it consequently results in a higher peak and pinch current,and therefore a relatively higher neutron yield[13]per Joule of stored energy.The overall size of this newly developed neutron source is just one-fourth of a previously developed source that produces an average neutron yield of ~4×109neutrons/shot at~7 kJ discharge[14].In this paper,along with a description of the system hardware design and construction,the results of characterization experiments carried out on this newly developed dense neutron generator with a closely integrated,compact,standalone pulsed power system are reported in detail.The five-phase Lee code(RADPFV5.13)[15]has also been used as a simulation tool to deduce and understand the corresponding changes in plasma dynamics and the pinch current parameter that is mainly responsible for a higher efficiency of neutron production in the newly developed PF device.

Figure 1.Construction and integration of various parts of the SPF device.

2.Experimental setup and diagnostics arrangement

The simple and energy-efficient pulsed power system of this small PF(SPF)device mainly comprises a single 12.5 μF/20 kV low inductance(<40 nH)metal-can energy storage capacitor and a maintenance-free sealed pseudospark switch along with its driver module.The pseudospark driver module provides a reservoir heater supply of ~5 V/2 A to control the hydrogen gas pressure inside the switch and ~5 kV fast impulse with a rise time <10 ns for its triggering[16].

To reduce the system inductance to minimum with enhanced reliability in operation,all the major parts of this neutron generation system(i.e.capacitor bank,switch and PF chamber)have been closely integrated without the use of flexible cables.A constructional schematic illustrating the assembly of the scheme is shown in figure 1.The anode of the pseudospark switch is rigidly connected over the capacitor head,whereas its discharge end to load(i.e.the cathode)directly interfaces with the anode of the PF chamber.The coaxial configuration of the current return helps in minimizing the overall system inductance and ensures symmetric flow of the discharge current,which further helps in balancing and distributing mechanical stresses generated due to electromagnetic forces.The specifications of this compact neutron generator are highlighted in table 1.

Table 1.Major specifications of the compact pulsed neutron source.

The stainless steel anode of 100 mm length(zo)and 8 mm radius(a)is concentrically placed through the squirrel-cage cathode structure in which six 8 mm diameter brass rods are fixed on a circular radius of 35 mm(b).To minimize the detrimental effect of the addition of ablated impurities into hot dense plasma from the anode top,a cylindrical hole of 11 mm diameter and 50 mm depth is bored at the centre of the anode.A quartz glass tube of 25 mm length with an inner/outer diameter of 12 mm/16 mm has been used as an insulator sleeve.In between the anode and ground return plates,a 5 mm thick Teflon®sheet has been used as sandwiched insulation.The PF chamber enclosing the coaxial electrode assembly has major dimensions of 0.1 m(φ)×0.2 m(h).As all the hardware parts are compactly integrated,residual inductance of ~75 nH was obtained for the total system(contributed by the capacitor,switch and PF tube),and this enables delivery up to ~200 kA peak current(at maximum rated voltage)in the quarter time period of about ~1.5 μs.The circuit parameters of the PF device in conjunction with an actual snap of the coaxial electrode assembly are shown in figure 2.Cois the total capacitance that is charged to a suitable voltage level Vch,and Loand Roare the static inductance and resistance,respectively,of the total electrical circuit.

Figure 2.A schematic representing the main electrical parameters of the PF device.

Figure 3.The standalone compact pulsed neutron generator.

As seen in the system photograph shown in figure 3,all the auxiliaries like a high voltage charger,pseudospark switch driver and other protection circuitry are housed within the same system cabinet.A constant current power supply of 30 kV/10 mA rating(procured from M/s Ionics Power Solutions Ltd,India)has been used for the charging of the capacitor bank.A 100 kΩ series resistance is used while charging to protect the charging power supply from high reverse voltage(that is generated during discharge)[17].Under adverse circumstances when the pseudospark switch fails to fire,then the entire energy stored in the capacitor is dumped through a solenoid operated switch into a 3 kΩ stack of series-connected bulk ceramic composition disc resistors.Optical-electrical and electrical to optical transmitter-receiver links of 50 m length are used for firing the neutron generator.

The diagnostics used for analyzing the performance of the SPF device are:(i)a Rogowski coil as an electrical diagnostic tool for probing the current derivative(di/dt)and seed current(∫I(t)dt)signals.These signals provide comprehensive information regarding axial acceleration and radial collapse/pinch phase plasma dynamics and,hence,are the most important indicators of the PF device performance;(ii)a silver activation counter(SAC)and3He detector for the neutron yield measurements.The SAC has been used for many years in several small and large DPF facilities for measuring the pulsed neutron yield due to its following inherent advantages:(1)neutron yield information is safely preserved in the counter after the exposure of neutron burst,(2)it has a sufficiently high cross section for thermal neutrons,(3)the short half life of its two stable isotopes enables rapid measurement with the use of simple counters,(4)a dynamic range of measurements with the SAC can cover a few orders of magnitude of neutron intensity depending on its dimensions[18].It is remarkable to note that silver has two isotopes Ag107and Ag109with abundance of 48.17% and 51.83%,respectively.Neutrons emitted from the PF device are slowed down while passing through the moderator of optimal thickness and induce two radiative capture nuclear reactions(see equations(1)and(2))in the foil that is made of natural silver[18]:

In the utilized setup,a silver foil thickness of ~250 μm has been used as activation material and is wrapped around three thin-walled Geiger-Muller(GM)tubes(LND-719),and they are symmetrically placed at the centre inside a hydrogenreach cylindrical moderator of high-density polyethylene(HDPE)of major dimensions with 150 mm diameter and 350 mm height.The diameter of each hole is 18 mm and the depth is 280 mm.All three GM tubes are biased at+900 V DC and their paralleled output is fed as input to the linear amplifier(LA); then,the LA output goes into the counter/timer unit that registers counts for a defined period.During the experiments,the silver activation detector setup was placed at a distance of 1 m from the source and it has a calibration factor of 2×105neutrons/count.The beta particles that are the result of silver activation reach the GM counter and finally produce the electrical impulses,which are proportional to the number of neutrons falling on the detector in 4πsr

A high sensitivity3He proportional counter in ‘charge integration mode’(CIM)has also been used for the secondary confirmation of the neutron yield in 4πsr[19].The cross section for the3He reaction is ~5330 barns for thermal neutrons,and the detection principle is based on the nuclear reaction shown below[20]:

As may be noted from the given nuclear reaction,the neutron causes the break-up of the nucleus into tritium nucleus,3H and a proton,1H.The triton and proton share the 765 keV reaction energy.Thus,the amount of energy deposited by this nuclear reaction leads to the release of energetic charged particles into the gas and,consequently,the produced multiplicative ionization reveals the detection of neutrons.The ionization potential of helium is about 25 eV.About~25 000 ions and electrons are produced per neutron interaction(cumulating charge of ~4×10−15Coulombs)[20].A3He neutron detector tube(#25He3/456/25NS)of nominal sensitivity 50 cps/nν has been used,and it is centrally placed inside the cavity of size 30 mm(φ)×350 mm(h)in a cylindrical moderator(i.e.hydrogenous plastic material DelrinTM)with major dimensions of 200 mm(φ)×500 mm(h)and ~80 mm thick wall for thermalizing neutrons.A preamplifier with a typical gain of ~150 mV pC−1was used for conditioning of the signal obtained from the3He detector,and its output is fed directly to the oscilloscope.To register the time-resolved history of generated hard x-rays(HXR)and neutrons,a detector assembly of a plastic scintillator(NE-102A with a thickness and diameter of 50 mm)coupled with a photomultiplier tube(EMI 9813BK)has been used.For electromagnetic shielding this detector assembly was enclosed inside a tightly capped light-proof aluminum housing[21].When the high energy photons of several tens to hundreds of keV strike on the plastic scintillator,its molecules get excited,and while de-excitation occurs,visible radiation is emitted.On the other hand,when 2.45 MeV energy neutrons strike on the plastic scintillator,molecular excitation is produced by transferring energy to recoil protons[22].When the emitted light that is followed by de-excitation falls on the photocathode of the attached photo-multiplier tube,photoelectrons are generated and multiplied producing a current pulse recorded in a fast oscilloscope.Experimental data were acquired on two digital storage oscilloscopes(Agilent DSO-7104B,4 GS/s,1 GHz)and a computer,and these were placed inside a Faraday cage to prevent the noise coupling.

3.Results and discussion

To standardize the performance of this compact neutron generator,the discharge voltage was kept fixed at ~17 kV for all shots,and the D2filling gas pressure was incrementally varied from 2 to 8 mbar.Consecutively,five shots were taken at each setting to obtain the average neutron yield.For the absolute measurement of pressure,a rugged barometrically compensated ‘capsule dial gauge’(#CG16K)from Edwards VacuumTMwas used.It covers the measuring range of 0 to 25 mbar,and has an accuracy of±2%of full scale deflection.

It has been well established that the radiation yield of the PF device maximizes when the focusing/pinching occurs at the instant while the discharge current is at its peak[22].Since the velocity of the current sheath in the axial and radial phases is predominantly governed by the D2gas pressure inside the chamber,hence it becomes important to investigate the optimum pressure at which maximum neutron yield is obtained for a particular discharge current or stored energy[22,23].The time evolution traces of typical current(I)and current derivative(di/dt)signals(with a dip at the first quarter time period),which were monitored by the Rogowski coil at~17 kV/5 mbar discharge,are shown in figure 4.

It may be noted from figure 4 that the progression of the current sheath from the breakdown phase to the completion of the axial rundown phase takes ~1.5 μs,and then the radial phase,including the final pinch breaking up,is typically over in <100 ns duration.Observation of multiple pinches as displayed in the time profile of the current and current derivative signals as a consequence of dynamic growth in plasma instabilities is quite random.However,some earlier studies on this aspect[24,25]have revealed its increasing/decreasing occurrences with filling gas pressure.The efficient pinch compression is verified by a strong dip in the current derivative signal,which is due to the rapid change in plasma impedance attributed by(i)fast-changing plasma inductance Lp(t),and(ii)growth in anomalous resistance Rp(t)caused by the collision of electrons with plasma waves when they reach a high intensity level[26].The higher magnitude of a distinct,sharp dip implies stronger pinching[27]resulting in efficient radiation emission from the pinched plasma column producing a burst of HXR and fusion neutrons.HXR and neutron pulses were discriminated on the basis of time-of-flight(TOF)signals obtained from the scintillator-photomultiplier(SPMT)detector assembly[28]that was placed at a distance of~3.2 m from the source.Figure 5 shows the measured TOF signal for a shot at ~5 mbar D2filling gas pressure.The time difference of ~25 ns between the dip of the di/dt signal and the first peak of the SPMT detector signal is due to dissimilar cable lengths.

The typical travelling speeds of x-rays and 2.45 MeV neutrons are ~3×1010cm s−1and ~1.96×109cm s−1,respectively; thus a time delay of ~150 ns between the two pulses obtained from the SPMT detector confirms their simultaneous generation from the PF device[22].The measured average pulse durations of the HXR and neutron pulse were 30±3 ns and 37±6 ns,respectively.

The time-integrated neutron yield in each pulse was measured using the SAC and3He detector in the proportional counter mode,and they are placed at a distance of 1 m from the PF axis in the side-on direction.Neutron yield estimation using the SAC was simply carried out by measuring the jump in counts(due to induced activity in silver foil by interaction with themalized neutrons)that is immediately followed after the discharge,and then the product of the net measured counts(after deducting the background)with a calibration factor gives the final measure of the neutron yield.The counting duration was set to 300 s to reduce the effect of statistical fluctuations between counting.Also,to obtain a more realistic estimate,prior to each discharge,a record of background counts was taken,and it was deducted from the total counts measured after the discharge.For the secondary confirmation of the measured neutron yield,a3He detector was also used.The3He detector tube signal obtained at a bias setting of+600 V is shown in figure 6.The area under this signal is then estimated and multiplied by the calibration factor(i.e.240 neutrons/μVs)to estimate the neutron yield[19].It is worth mentioning here that the estimated calibration factor is specific to the bias voltage setting and the calibrated distance between the source and detector.

Figure 4.Oscilloscope traces of typical current and current derivative signals for discharge at ~17 kV/5 mbar.

Figure 5.The signal from the SPMT detector placed at 3.2 m distance in the side-on direction.

Figure 6.The 3He detector output signal through the charge sensitive preamplifier.

The measured average neutron yield and time-to-pinch(i.e.time between the start of the breakdown phase until the end of the radial compression phase)at various D2pressures are shown in figure 7.The filling gas was periodically refreshed to reduce the effect of contamination on radiation yields.

As shown in figure 7,a maximum average neutron yield of ~(2.3±0.3)×108neutrons/shot was produced at a D2gas pressure of ~5 mbar.The corresponding time-to-pinch was ~1.5 μs.The further increase observed in the time-topinch at increased pressures is due to excess loading on the current sheath[23].It is clearly evidenced from the shown results that the PF device produces maximum neutron yield only in a particular pressure range[29].

This observation is also supported by the thermonuclear and beam-target hypothesis of neutron production[27].It is remarkable to note that neutron yield in a wide energy range of PF devices conventionally follows the proportionality of peak current with an index of ~4(i.e.I4)[13]; subjected focusing/pinching occurs at the instant while the discharge current is at its peak.Practical realization of this condition has interdependence on anode length,peak current/charging voltage and filling gas pressure.Since the anode length and peak current/charging voltage are fixed,then the D2gas pressure is the only variable parameter that was fine-tuned to satisfy the conditions for obtaining the optimum neutron yield.

Figure 7.Average neutron yield and time-to-pinch versus D2 gas pressure.

Figure 8.The measured and ‘fitted’ current trace for operation at 17 kV/5 mbar.

A plausible explanation for relatively lower neutron yields at low pressures is higher acceleration of the current sheath that consequently results in much faster growth of Rayleigh-Taylor(RT)instability and breaking of the pinched plasma column prematurely[30].At optimum pressure,the plasma sheath gets adequately slowed down thereby increasing the RT instability growth time that enhances compression of the pinched plasma column to higher density.A consequent increase in confinement duration and density thus results in a higher reaction rate probability and more neutron yield[31].It is clearly evidenced in the shown results that increasing the pressure beyond the optimal range causes the time-to-pinch to increase further at a later instant when the discharge current has crossed its peak.Heating of pinched plasma reduces at less current and,therefore,the neutron yield reduces.It is also important to note that for efficient focusing with pure D2filling,the specific energy of the plasma sheath must be ≥1 MJ/g for swept mass to produce the optimum neutron yield[23,32].

The reported average neutron yield of some similar energy range PF devices[11,12,33]and that of our PF device are shown in table 2 for comparison purposes.The relative comparison of average neutron yield(Yn)versus stored energy(Eo)clearly indicates that this new system poses a higher neutron yield than the other listed devices per Joule of stored energy.

It is remarkable to note that the neutron yield scales with peak(Ipeak)and pinch(Ipinch)currents as Yn~(9×

where Ipinchis the current flowing through the pinch at the start of the slow compression phase,niis the ambient ion density,rpis the radius of the plasma pinch,b is the cathode radius,σ is the cross section for the fusion reaction,Vmaxis the maximum voltage induced by the current sheath collapsing radially towards the axis and Cnis a constant.Neutron yield estimation using this beam-target mechanism is comprehensively included in the five-phase Lee model RADPFV5.13[15].

In the present work,actual values of Ipeakand Ipinchfrom the measured total discharge current waveform are deduced by fitting a numerically computed current trace upon an experimentally measured current trace by suitably adjusting the swept mass factor fm/fmrand the current shedding factor fc/fcrfor the axial/radial phases,respectively,in the Lee code[34].Plasma dynamics in all three major phases of the PF device operation and its efficient focusing are clearly evident in the discharge current trace signal obtained on the oscilloscope[22].

The primary inputs required for running the Lee code[15,34]are the capacitor bank parameters(Co,Loand Ro),the focus tube parameters(a,b and z0)and the operational parameters(Vch,p and filling gas properties).It is also important to note that since the code is charge-consistent,and Loand Rovary dynamically during focusing action,the computed amplitude of the peak current is a more accurate value than the measured amplitude.A ‘fitted’ discharge current trace of the SPF device for operation at 17 kV/5 mbar D2gas pressure is shown in figure 8.The fine-tuned electrical‘circuit parameters’and values of the‘model parameters’that have been obtained for ‘best fit’,along with ‘peak and pinch current’ estimations for all the DPF devices listed in table 2 are summarized in table 3.

Table 2.A relative comparison of Eo and Yn reported by various laboratories.

Table 3.Model parameters and simulation results obtained for various DPF devices.

As the estimated peak/pinch currents are 170 kA/142 kA at ~17 kV discharge in the SPF,therefore,according to suggested empirical scaling equations[13]as well as from the Lee code,a neutron yield typically in the order of ~107neutrons/shot is expected; however,experimentally,a one order higher magnitude of neutron yield,i.e.~2.3×108neutrons/shot,was measured.This unexpected superior yield may be defended by the extended current dip with good depth and duration observed in the discharge current trace that is shown in figure 8.From the fitting of the computed current trace over the measured trace it may be seen that the experimentally measured dip in the discharge current trace signal extended much beyond the computed dip.All iterations were attempted using model parameters,but the computed current dip could not be made to fit over the extended portion of the measured current dip.

A comprehensive review of various parameters of DPF devices shown in tables 2 and 3 reveal that the SPF,KSUDPF[12]and UNU-ICTP[11]devices fall into the category of systems with higher circuit inductance[35],and their experimentally measured and computed neutron yield typically differ by an order of magnitude,whereas in NX-2 like devices,those that have very low circuit inductance,good agreement is observed in such systems between measured and computed neutron yields[35].A plausible explanation regarding the anomaly in measured and computed neutron yields and the noticeable signature of the long extended dip in the discharge current trace in PF devices of higher circuit inductance is mainly due to a higher ratio of static and pinch inductance,i.e.(Lo+La)/Lp,where Lois the static residual circuit inductance of the PF device,Lais the dynamic inductance of the axial part of the focus tube and Lpis the dynamic pinch inductance that is typically in the range of 5 nH to 10 nH.This higher inductance ratio results in bulk residual inductive energy that is gradually transferred into the pinch instabilities with a larger time constant.The signature of a strong extended dip in the discharge current trace is mainly the consequence of a rapid change in plasma impedance attributed by fast-changing plasma inductance Lp(t),and rapid growth in anomalous resistivity Rp(t).Hence,the 1/e time scale(i.e.Lp/Rpdepicted as an extended dip in the current trace)in which the current drops to ~37% is mainly decided by the lumped circuit parameters[34,35].

Further review of the Lee code simulation results shown in table 3 for various DPF devices also infers that circuit inductance Lohas a crucial role in limiting the peak/pinch currents that may be extracted from per kJ of stored energy.The SPF and KSU-DPF[12]were both operated at the same stored energy of ~1.8 kJ,but the Ipeak/Ipinchcurrents were 172 kA/142 kA and 137 kA/94 kA,respectively.The higher Ipeak/Ipinchin our SPF device is mainly the consequence of~40% smaller circuit inductance(i.e.~75 nH)than KSUDPF(i.e.~123 nH)[12].Similarly,it may be noted that even though the SPF and UNU-ICTP[11]devices were operated at different stored energies of ~1.8 kJ and ~2.7 kJ but their extracted peak currents(Ipeak)are nearly the same,i.e.170 kA and 164 kA,respectively,because of 30% less circuit inductance in the SPF device(i.e.75 nH versus 110 nH),conversely a higher fraction of current goes into the pinch of the SPF device and thus results in a relatively higher neutron yield(at least ~2×)at ~33% less stored energy than the UNU-ICTP[11]device.

It is remarkable to note that the‘speed factor’is typically about 89±8 kA cm−1Torr−1/2in a wide energy range of D2fuelled PF devices,and it is basically the measure of driving magnetic energy per unit mass associated with the peak discharge current[36].In all the PF devices with higher system inductance[35]as listed in table 3,the values of the speed factor for the neutron optimized regime are typically in the range of 100 to 110 kA cm−1Torr−1/2indicating that the plasma sheath speed in these devices in the axial and radial phases is relatively on the higher side than their normal range,attributing better compression and higher shock heating of the pinched plasma column[37]and thus supporting enhanced radiation yield.

4.Conclusion

The newly designed and developed SPF device has been successfully demonstrated as a compact,efficient pulsed neutron source producing an average yield of ≥2×108neutrons/shot with pure D2filling that may be conveniently utilized for various applications,such as NAA,calibration and testing of newly developed fast/thermal neutron detectors,and testing the shielding/moderation effectiveness of fast neutrons in new composite materials.The closely packed hardware integration in a small unit has played a crucial role in limiting the static system inductance(Lo)≤75 nH.The design of the PF electrode dimensions is well matched with the electrical characteristics of the driving current pulse,allowing maximum pinch compression to coincide with the peak of the discharge current in a quarter time period of about~1.5 μs.In conclusion,causes of the higher neutron generation efficacy of the newly developed SPF device in comparison to other devices with stored energies in a similar range are enumerated as follows.

1.A reduction in static inductance(Lo)of the electrical circuit enhances the peak current and pinch current,which in turn enhance the neutron yield.

2.From the experimental measurements and Lee code simulation results,it is clearly evident that the Ipeakand Ipinchmainly depend on the value of the static inductance Locompared to the dynamic inductances of the PF.As Lois reduced,the ratio of Ipinch/Ipeakimproves and,e.g.irrespective of the different energy stored in the SPF and UNU-ICTP[11]devices,both systems deliver peak currents in the similar range as 170 kA and 164 kA,respectively; but the pinch current is higher in the SPF device than the UNU-ICTP[11]device(142 kA versus 94 kA)owing to less circuit inductance(75 nH versus 110 nH).This case study also concludes that the Ipeakalone cannot be considered as a valid neutron yield scaling parameter,especially for the devices with significantly different and higher Lo.Better consistency in neutron yield scaling has been demonstrated with Ipinchas the reliable scaling parameter[38].

3.Observation of extended dip in discharge current traces with higher depth and duration depicts the influence of higher system inductance in conserving large inductive energy.The higher static/pinch inductance ratio(Lo+La)/Lphelps in the gradual transfer of stored energy into the pinch until the end of the radial compression phase with a larger time constant[34,35].Hence,it is realized that Loalso has a pivotal role in enhancing the stabilization of the high-density pinched plasma column enriching the beam-target mechanism for neutron generation.

4.The presented results and analysis also infer that,for the more realistic estimation of neutron yields in PF devices with higher static/pinch inductance ratios[35],more data need to be collected and analyzed to obtain updated index values of Ipinchand Ipeakin scaling equations[13]as scaling parameters.

5.The speed factor/drive parameter is an indicative measure of the speed of plasma in both the axial and radial phases,and its noticeable constancy in the higher range of 100 to 110 kA cm−1Torr−1/2along with strong focusing characteristics corroborates higher shocked heating and better compression of the pinched plasma column resulting in enhanced neutron yield.

Acknowledgments

The authors are grateful to Shri D Venkateswarlu,Project Director,BARC Facility,Visakhapatnam,for his consistent encouragement and support in the development of this compact pulsed neutron source.

ORCID iDs