Abstract: Limestone gypsum desulfurization technology is the most widely used flue gas desulfurization technology in China. As far as limestone gypsum method is concerned, there are many factors affecting its desulfurization efficiency. It is found by chance that the scale inhibitor widely used in coal-fired power plants also has a great impact on the desulfurization efficiency of limestone gypsum method. Based on the completed experimental results and understanding of limestone gypsum method, this paper briefly expounds the author's views and speculations, in the hope of providing a possible research direction for limestone gypsum desulfurization.
Keywords: scale inhibitor; limestone gypsum desulfurization; desulfurization efficiency
1 实验目的
某电厂脱硫项目试运以来,在脱硫岛入口烟气条件在设计值范围内(2478mg/Nm3、100%BMCR工况、实际氧)的,出现了脱硫效率只能维持在90%左右的情况(设计为95%),调试单位对该系统的pH值进行调整,系统效率仍然达不到设计值,而且石膏中的CaCO3增加很多,针对这种情况,本实验对该厂的石灰石和系统用水进行实验,寻求解决此问题的方法。
2 实验样品及依据
2.1 试样的分析
2.2 反应速率计算式
2.3 实验依据
采用电力行业标准DL/T 943-2015《烟气湿法脱硫用石灰石粉反应速率的测定》
3 实验数据及分析
4 更换工艺水后的吸收塔运行数据
为验证实验结果,吸收塔采取工业水(水质接近黄河水)入塔的运行方式进行试运,且保证基本不使用工艺水入塔,试运时机组负荷基本在70%BMCR以上,原烟气SO2浓度接近设计值,连续运行8小时,吸收塔的脱硫效率明显提高,普遍在95%以上,最高值达到了98%。逐渐在吸收塔更换添加了阻垢剂的工艺水运行,吸收塔脱硫效率逐渐下降。
5 结论
本实验存在一定局限性,首先是样品种类不多;其次是由于厂方不肯提供阻垢剂的组成配方,所以本实验不能证明实验结果对所有阻垢剂有效;最后是由于时间、场地、设备等原因,本实验有些数据不够完整。但实验仍然具有很大的意义,为研究石灰石石膏法脱硫提供了一个方向。
从实验可以看出,阻垢剂大幅降低了石灰石的溶解速率,降低了脱硫效率,初步猜测原因如下:
阻垢剂能够阻止结垢,但会增加水中钙离子的浓度,因为同离子效应,降低了石灰石的溶解速率及溶解总量,从而使溶液中起缓冲作用的未电离的H2CO3总量减少,导致溶液缓冲性降低,在溶液吸收SO2时pH值降低过快,降到临界pH值后不再吸收SO2,最终导致脱硫效率的降低。