Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
2011-08-15马立泰MaLitaiDepOrthopWestChinaHospSichuanUnivChengdu610041ChinaOrthopTrauma201113110113
马立泰(Ma Litai,Dep Or-thop,West China Hosp,Sichuan Univ,Chengdu 610041)…∥China J Orthop Trauma.-2011,13(2).-110~113
Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
马立泰(Ma Litai,Dep Or-thop,West China Hosp,Sichuan Univ,Chengdu 610041)…∥China J Orthop Trauma.-2011,13(2).-110~113
ObjectiveTo explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.MethodsA retrospective study was done to analyze the 172 patients who had been consecutively treated by anterior internal fixation for thoracolumbar fractures between May 2004 and January 2008.They were 124 men and 48 women,with a mean age of 39.0 years(from 15 through 70 years).According to the internal fixation system,they were divided into 4 groups:Z-plate(63 cases),Antares(45 cases),Profile(50 cases)and Mono-screw-rod(14 cases).Radiographic scans were used to measure and compare the coronal Cobb angles between preoperation and postoperation as well as between the 4 groups.ResultsAll the patients were followed up for 8 to 49 months(mean,39 months).The mean coronal Cobb angle was 0.8°±3.9°before operation,3.2°±4.1°immediately after operation,and 3.5°± 4.2°at the final follow-up.In all the cases and the 4 groups,the postoperative lateral angulation was significantly larger compared to that of preoperation(P <0.05),but there was no significant difference between the last follow-up and postoperation(P >0.05).There were no significant differences in multiple comparison of postoperative coronal Cobb angles between the 4 internal fixation systems(P >0.05).There were no significant differences in ratio of postoperative lateral angulation between the 4 internal fixation systems either(P >0.05).ConclusionThe current internal fixation systems are not associated with the postoperative lateral angulation in treatment of thoracolumbar fractures.12 refs,1 fig,4 tabs.
(Authors)
杂志排行
外科研究与新技术的其它文章
- Treatment for 63 cases of the elderly with choledocholith by duodenoscope
- Meta-analysis of the Resolution rate of Type 2 diabetes mellitus in patients undergoing Roux-en-Y gastric bypass surgery
- Quantification of spatial expansion of cervical tumours using Magnetic Resonance Imaging
- Effect of the tumescent infiltration solution temperature on body temperature
- Histologic analysis and long-term effect of acellular dermal matrix combined with autologous thin split-thickness skin graft
- Experimental study of the effect of adipose stromal vascular fraction cells on the survival rate of fat transplnio